Mach-Zehnder interferometric system for measuring the refractive indices of uniaxial crystals
Year: 2003
Authors: De Nicola S., Ferraro P., Finizio A., De Natale P., Grilli S., Pierattini G.
Autors Affiliation: Istituto di Cibernetica del CNR, Via Campi Flegrei 34, 80078 Pozzuoli (NA), Italy;
Istituto Nazionale di Ottica Applicata, Sez. di Napoli, Via Campi Flegrei 34, 80078 Pozzuoli (NA), Italy
Abstract: We report a new interferometric technique for measuring the ordinary and extraordinary, refractive indices of uniaxial crystals. The technique is based on the measurement of the rotation-dependent phase changes of the optical path length in crystal plates. Accurate measurement of the phase shift as a function of the rotation of the sample is achieved by using a fast-Fourier-transform based fringe analysis method for phase retrieval. The principle of the method is discussed and measurements of the ordinary and extraordinary refractive indices of a lithium niobate crystal are reported.
Journal/Review: PROCEEDINGS OF SPIE
Volume: 5036 Pages from: 594 to: 599
KeyWords: lithium niobate; interferometry; DOI: 10.1117/12.498644Citations: 2data from “WEB OF SCIENCE” (of Thomson Reuters) are update at: 2024-11-24References taken from IsiWeb of Knowledge: (subscribers only)Connecting to view paper tab on IsiWeb: Click hereConnecting to view citations from IsiWeb: Click here